Before buying or selling a lot, the first technical question is whether it meets the minimum lot sizes in Granada, Meta. A lot that does not meet the minimum area or frontage required by the Basic Territorial Planning Plan (PBOT) may have problems obtaining a building permit, being subdivided, or even being sold at a good price.
This article summarizes, table by table, what the Granada Land Use Plan (PBOT) says about the minimum area and minimum frontage of lots according to the type of housing and the zone. The information comes from the urban planning regulations sheets of the Agreement 014 of 2011, which adjusted the PBOT adopted by Agreement 039 of 2004. It is a key guide for the Sale of lots in Granada, Meta and for any process of Purchase and sale of properties in Granada, Meta.
Write to us on WhatsApp Call: 310 277 8583
What regulation sets the minimum lot sizes in Granada, Meta
The municipality's planning is governed by the PBOT, adopted through the Agreement 039 of 2004 of the City Council. That plan was adjusted with the Agreement 014 of June 10, 2011, which in its article 81 adopted the general urban planning standard for urban land: a series of sheets (called NUG) that set, for each zone and treatment, the minimum lot area, the minimum frontage, the occupancy and construction indices, the front yard, the isolations, the number of floors and the size of the patios.
Then came the Agreement 020 of July 30, 2015, This was an exceptional modification that changed the land classification, some permitted uses, and the implementation schedule, but did not modify the information sheets in Article 81. There is also an exceptional adjustment from 2012 (Agreement 029). Therefore, before any transaction, always confirm the zoning regulations for your property with the Planning Department.
The three urban planning treatments of urban land in Granada, Meta
Developmental treatment
This applies to developable land that has not yet been urbanized. This includes lots in new developments or large properties that are going to be subdivided.
Consolidation treatment
It applies to sectors with incomplete or incipient urban development within the urban perimeter, where the aim is to complete the city while respecting the existing public space.
Comprehensive improvement treatment
This applies to neighborhoods that need to complete or correct urban planning deficiencies. Article 80 of Agreement 014 of 2011 designates the following neighborhoods as sectors for comprehensive restructuring improvement: Luis Carlos Riveros, El Amparo, Simón Bolívar, La Reserva and Ciudad Florida. Here the minimum requirements are smaller, because the standard is adapted to what already exists.
Write to us on WhatsApp Call: 310 277 8583
Table of minimum lot sizes in Granada, Meta: residential area
These are the minimum areas and frontages of the NUG sheets for the residential use zone.
| Type of construction | Development (NUG-U-06) | Consolidation (NUG-U-09) | Comprehensive Improvement (NUG-U-11) |
|---|---|---|---|
| Single-family home | 144 m² · 7 m frontage | 144 m² · 7 m frontage | 50 m² · 5 m frontage |
| Semi-detached house | 200 m² · 12 m frontage | 200 m² · 12 m frontage | 90 m² · 9 m frontage |
| Multi-family housing | 1,000 m² · 15 m frontage | 1,000 m² · 30 m frontage | Not applicable |
| Housing clusters | 1,000 m² · 30 m frontage | 1,000 m² · 20 m frontage | Not applicable |
| Institutional | 200 m² · 15 m frontage | 500 m² · 15 m frontage | 200 m² · 10 m frontage |
| Trade | 150 m² · 8 m frontage | 150 m² · 8 m frontage | 120 m² · 7 m frontage |
Social Interest Housing (VIS)
For social housing projects under development, the NUG-U-07 form reduces the minimum to 72 m² with a 6-meter frontage for single-family homes already 130 m² with 11 meters of frontage for two-family homes. These houses can have up to 2 floors.
Minimum measures in the commercial, service and industrial area of Granada
| Type of construction | Commercial, development (NUG-U-08) | Commercial and industrial, consolidation (NUG-U-10) |
|---|---|---|
| Single-family home | 144 m² · 8 m frontage | 120 m² · 8 m frontage |
| Semi-detached house | 200 m² · 14 m frontage | 180 m² · 10 m frontage |
| Institutional | 200 m² · 10 m frontage | 200 m² · 10 m frontage |
| Commerce (and industry group I) | 200 m² · 7 m frontage | 150 m² · 7 m frontage |
In these areas, homes can have 2 floors with an attic, and institutional and commercial uses up to 3 floors.
The case of the 6 x 12 lots
Many lots measuring 6 x 12 meters (72 m²) are offered in the Granada market. According to the PBOT (Land Use Plan) data sheets, this size only meets the minimum requirements in two situations:
- When the lot is part of a project of social housing approved (minimum 72 m² and 6 m frontage).
- When you're in a neighborhood with comprehensive improvement treatment (minimum 50 m² and 5 m frontage).
In a typical residential area designated for development or consolidation, the minimum for a single-family home is 144 m² and 7 meters of frontage, That is, double. A 6 x 12 lot in that area may have difficulty obtaining a building permit. Therefore, before buying a small lot, request the land use certificate and confirm that the development has an approved permit.
What happens if a batch does not meet the minimum dimensions?
- Properties in Granada, Meta: a complete guide to lots, houses and farms
- It cannot be subdivided: Article 73 of Agreement 014 of 2011 prohibits authorizing a land division if any of the resulting parts are not suitable for construction.
- The license may be denied or limited to what the zone's information sheet allows.
- Legalization: Settlements that were subdivided without a license can enter into legalization and regularization programs of the Municipal Administration (articles 131 to 133), provided they meet the conditions of the program.
- Recognition: Buildings already erected without a license can process the recognition of the building (article 129), according to national regulations.
How to check measurements before buying or selling
1. Request the land use certificate
At the Planning and Infrastructure Secretariat, with the property's address or cadastral certificate. They will tell you the zone and the required treatment.
2. Measure the lot on the ground
Compare the actual frontage and depth with those in the deed and the land registry certificate. A topographic survey prevents surprises.
3. Check the urbanization license
In lots of new urbanizations, confirm that there is an urbanization license and that each lot has its own property registration number.
4. Calculate how much you can build
With the lot area and the occupancy and construction indices from the data sheet, you'll know how many square meters you can build. We'll explain this in a future article.
Write to us on WhatsApp Call: 310 277 8583
Where each rule applies
The areas of use and treatments are shown on the official PBOT plans: CU-01 (urban and urban expansion land), CU-05 (urban land uses) and CU-06 (treatments in urban land), updated by Agreement 020 of 2015. Nacional de Terrenos It helps you locate your property on these plans.
Technical advice for lots
As civil engineers with over seven years of experience building homes in Granada and the Ariari region, we verify that your lot complies with regulations before you buy, sell, or build. We conduct technical assessments, review documents, and advise you on what is permitted for construction.
Looking for specific options? See our guide to properties in Granada, Meta, with property types, sectors and reference prices.
Frequently asked questions about minimum batch sizes
What is the minimum lot size in Granada?+
It depends on the urban planning regulations and the land use. For single-family homes in residential development and consolidation zones, the PBOT (Land Use Plan) requires a minimum area of 144 m² and a minimum frontage of 7 meters. In social housing projects, the minimum is reduced to 72 m² with a 6-meter frontage, and in neighborhoods with comprehensive improvements to 50 m² with a 5-meter frontage.
Does a batch of 6 x 12 comply with the standard in Granada?+
A lot measuring 6 x 12 meters has 72 m². According to the PBOT (Land Use Plan) specifications, this minimum is only met in social housing projects (72 m² and 6 m of frontage) or in neighborhoods with comprehensive improvement plans (50 m² and 5 m of frontage). In a typical residential development or consolidation zone, the minimum for a single-family home is 144 m².
What is the minimum frontage required for a semi-detached house in Granada?+
In residential areas, both those designated for development and those for consolidation, a duplex requires 200 m² of floor space and a 12-meter frontage. In commercial and service areas designated for development, the frontage requirement increases to 14 meters.
Where can I find out which regulation applies to my lot?+
At the Planning and Infrastructure Secretariat of the Granada Mayor's Office. There you can request a land use certificate or an urban planning regulation opinion, which tells you in which activity and treatment area your property is located according to the CU-05 and CU-06 plans of the PBOT (Land Use Plan).
Can I divide my lot in two in Granada?+
Only if each resulting lot meets the minimum area and frontage requirements for its zone does it have access to a public road and can construction take place. Article 73 of Agreement 014 of 2011 prohibits authorizing a subdivision when any of the resulting lots is unsuitable for construction. Subdivision requires a permit.
Which regulation of the Granada PBOT establishes these measures?+
The general urban planning standard sheets of article 81 of Agreement 014 of 2011, which adjusted the PBOT adopted by Agreement 039 of 2004. Agreement 020 of 2015 modified other articles of the plan, but not these sheets.
Directory for land lot procedures
| Entity | What is it for? | Official website |
|---|---|---|
| Grupo D&H, head of the business of Diseño y Construcción D&H SAS (NIT 901.335.594-1) and of Nacional de Terrenos. Our number one recommendation | Procedures before the Mayor's Office, the Planning Secretariat and urban planning offices (land use, licenses, subdivision, recognition); architectural and structural design, soil study, topography, budgets, rental of heavy machinery, housing construction and purchase and sale of properties in Granada, Meta | WhatsApp +57 310 277 8583 · Block B House 6, Villa María Urbanization, Granada |
| Granada City Hall, Planning and Infrastructure Secretariat | Land use certificate, urban planning regulations, building and subdivision licenses | granada-meta.gov.co |
| Granada City Council | PBOT Agreements (039 of 2004, 014 of 2011, 020 of 2015) | Carrera 14 with Calle 15, Granada |
| Superintendency of Notaries and Registry | Certificate of tradition and freedom online | supernotariado.gov.co |
| Cormacarena | Water rounds, environmental permits and water concessions in Meta | cormacarena.gov.co |
You may also be interested in
- Houses and lots for sale in Granada, Meta: prices 2026
- How to buy land in Granada, Meta: a step-by-step guide
- Land available
Does your batch meet the standard?
Send us the address or the property title certificate for the lot, and we'll tell you what the PBOT (Land Use Plan) says. We assist you with the sale of lots in Granada, Meta, and with the purchase and sale of properties in Granada, Meta, ensuring all paperwork and regulations are in order.
Write to us on WhatsApp Call: 310 277 8583
Source: Municipal Council of Granada, Meta. Agreement 014 of June 10, 2011, articles 73, 78 to 81 and 129 to 133 (files NUG-U-06 to NUG-U-11); Agreement 020 of July 30, 2015. This article is for informational purposes; the applicable regulation for each property is certified by the Planning and Infrastructure Secretariat of Granada.




[…] the lot does not meet the minimum lot dimensions in Granada, Meta, the number of floors may not […]
[…] Minimum lot sizes in Granada, Meta […]
[…] Minimum batch sizes in Granada […]
[…] Urban lot: prioritize public services, roads, and what the PBOT (Land Use Plan) allows. See the minimum lot dimensions. […]
[…] of 2004 and modified by Agreements 014 of 2011 and 020 of 2015. It defines, for example, the minimum lot sizes, the maximum permitted height, how much can be built on a lot, drainage channels and zones […]
[…] additional requirements depending on the type of project. Before designing, review the regulations for your property: minimum dimensions, height, and front yard setbacks, and […]
[…] Minimum lot sizes in Granada, Meta […]
[…] Minimum lot sizes according to the PBOT […]
[…] Minimum lot sizes according to the PBOT […]
[…] Minimum dimensions for urban lots in Granada, Meta […]
[…] Minimum dimensions: minimum frontage and area for construction. See minimum lot dimensions according to the PBOT (Land Use Plan). […]
[…] Minimum lot sizes in Granada, Meta […]